Back to Top

1
Hi, Guest!

Sick Maihak Volume Flow Measurement

Update Terakhir
:
11 / 02 / 2022
Min. Pembelian
:
0

Harga

CALL
PT. INTI KARYA KARISMA adalah suatu perusahaan dagang yang berkembang sangat pesat, khususnya dalam bidang penyediaan barang dan alat - alat untuk kebutuhan industri yang ada di Indonesia, meliputi bidang Valve - Valve, Automation System dan Electrical Components.

Detail Sick Maihak Volume Flow Measurement

FLOWSIC600 Ultrasonic Gas Flowmeter The FLOWSIC600 measures the actual volumetric flow rate, actual accumulated volume, gas velocity or velocity of sound in gases with high measurement acuraccy over wide measuring ranges. It is ideal for flows with high dynamics. The FLOWSIC600 2PLEX is ideal for custody transfer because of its 4-path meter for billing and the integrated 1-path meter for monitoring of internal faults. Read more > Applications The FLOWSIC600 is suitable for custody transfer metering, for company internal metering and billing as well as for automatic control and measurement tasks in the process measurement. Fields of application are all divisions of natural gas industry, power plants, the chemical and petrochemical industry, the cement and other consuming plants. Technical specification Measuring values Actual volumetric flow rate; actual accumulated volume; gas velocity; velocity of sound in gases Measuring principle ultrasonic transit time difference Maximum flow rate 400 ... 100 000 m³ / h ( 14 125 ... 3 531 467 ft³ / h) ; depending on nominal width Repeatability < 0.1 % of reading Typical uncertainty 1 measuring path: + / - 2.0 % 2 measuring paths: + / - 1.0 % 4 measuring paths: + / - 0.5% , + / -0.2 % after high pressure calibration ( with straight inlet/ outlet section 10D/ 3D or 5D/ 3D with flow straightener) Number of measuring paths 1, 2 or 4 Measured gas pressure 0 ... 250 barg ( 3625 PSI) , up to 450 barg ( 6526 PSI) on request Measured gas temperature -30 ... + 180 ° C ( -22 ° F ... + 356 ° F) , -194 ° C ... + 280 ° C ( -317 ° F ... + 536 ° F) on request Explosion protection Europe ( ATEX) : - II 1/ 2 G EEx de ib [ ia] IIA T4 or II 1/ 2 G EEx de ib [ ia] IIC T4 - ultrasonic transducers are intrinsically safe " ia" USA/ Canada ( CSA) : - Class I, Division 1, Groups D T4; Class I, Division 2, Groups D T4 - Class I, Division 1, Groups B, C, D T4; Class I, Division 2, Groups A, B, C, D T4 - ultrasonic transducers are intrinsically safe " ia" Measured value output HF pulse ( NAMUR or Open Collector) ; 4 ... 20 mA ( active/ passive) ; insulated Interfaces Modbus ASCII ( RS485) and Modbus RTU ( RS485) : configuration, measured values, output and diagnosis or HART: configuration, measured values, output and diagnosis Installation length 3D/ 5D, 150 ... 2400 mm, depending on nominal size Nominal size DN 50 ( 2" ) ... DN1200 ( 48" ) Material meter size DN600/ 24" : steel 1.1120 / ASME A216 WCC, flanges ASTM A105; stainless steel 1.4408 / ASME A351 Gr. CF 8M, flanges 1.4404 / A182 Gr. F316L Remarks Options can be delivered as special versions on request.
Tampilkan Lebih Banyak
Kontak Kami